RO System
Features
- Standard package and pre- assembled systems
- Assembly checked and tested
- Quick installations & start- up
- Customized features to accommodate specific needs
- Short delivery period
- Stringent quality control checks
- Components with international standards
- Ready availability of spares
- All India service back-up
Applications
- Drinking water plants
- Boiler feed water
- Cooling tower feed water
- Chiller/coler feed water
- Food and bevarages water needs
- Commercial kitchen equipment water needs
- Dialysis machine water needs
- Process water plants
- Water bottling plants
Only inlet- outlet & power connection set- up
Technical Specifications
- Thin film composite RO membrane for optimum water quality
- Stainless Steel multi- stage centrifugal pump
- FRP membrane pressure vessels
- Dual media filter in FRP
- Anti- scalant dosing system
- High pressure pipe line in SS (Optional)
- Frame in MSEP
- Maximum system availability with clean-in-place connections
- Pre-filter housing & cartridge 20" full flow
- Filter feed pump
- 12 months warranty against manufacturing defects from date of dispatch
Instrumentation & Control
- User friendly controller
- Low pressure shut-off
- High pressure trip
- Tank low level trip
- Pre-filter pressure gauge
- Pump discharge pressure gauge (liquid filled)
- Reject line pressure gauge (liquid filled)
- Flow meter for product water
- Flow meter for reject water
- In- built conductivity meter in control panel
|
FWR0100
|
FWR0250
|
FWR0500
|
FWR0750
|
FWR01000
|
FWR01500
|
FWR02000
|
Product Flow (LPH)
|
100
|
250
|
500
|
750
|
1000
|
1500
|
2000
|
Feed Flow (LPH)
|
800
|
1400
|
1600
|
1800
|
2000
|
2500
|
3100
|
Reject Flow (LPH)
|
700
|
1150
|
1100
|
1050
|
1000
|
1000
|
1100
|
Connection
|
Feed Water Inlet
|
1" (FNPT)
|
1" (FNPT) |
1" (FNPT) |
1" (FNPT) |
1" (FNPT) |
1.25" (FNPT) |
1.5" (FNPT)
|
Product Outlet
|
3/4" (FNPT)
|
3/4" (FNPT) |
3/4" (FNPT) |
3/4" (FNPT) |
3/4" (FNPT) |
1" (MNPT)
|
1" (MNPT)
|
Reject to Drain Outlet
|
3/4" (FNPT)
|
3/4" (FNPT) |
3/4" (FNPT) |
3/4" (FNPT) |
3/4" (FNPT)
|
1" MNPT)
|
1" (MNPT)
|
Membrane
|
Membrane Size
|
4" x 40"
|
4" x 40"
|
4" x 40:"
|
4" x 40"
|
4" x 40"
|
4" x 40"
|
4" x 40"
|
Membrane Quantity
|
1 No.
|
1 No.
|
2 No.
|
3 Nos.
|
4 Nos.
|
6 Nos.
|
8 Nos.
|
Power consumption
|
|
|
|
|
|
|
|
KW
|
1.1
|
2.75
|
2.75
|
2.75
|
2.75
|
4.2
|
4.2
|
HP
|
1.5
|
3.75
|
3.75
|
3.75
|
3.75
|
5.5
|
5.5
|
Phase
|
1
|
3
|
3
|
3
|
3
|
3
|
3
|
Vessel Array: System Dimensions
|
Vessel Quantity
|
1
|
1
|
1:1
|
1
|
1:1
|
1:1
|
2:1
|
HxWxD (in mm)
|
1750 x 835 x 870
|
1750 x 835 x 870
|
1750 x 835 x 870
|
2100 x 3800 x 800
|
2100 x 2650 x 800
|
2200 x 3800 x 900
|
2200 x 2650 x 1000
|
Shipping Weight (kg)
|
200
|
350
|
400
|
500
|
850
|
1150
|
1300
|
Additional options available with high pressure line with S.S. 304; Pipe line with S.S. 304
Note
Performance specification based on
- +25C feed water
- SDI <3
- TDS below 2000ppm
- pH 7.50- 8.50
- Absence of chlorine in raw water
|